Page 65 - Koi Net - On-Line Koi Magazine - Issue 36
P. 65

If the return is on the pond edge, you will easily have                             The higher this head height, the less water comes out of
                             an inch or a few cm which is very little, and a small                               the hose or pipe behind the pump. As can be seen in
                             consideration here, the returned water should flow by                               the diagram opposite, this has a huge impact. (I have
                             gravity back into the pond and not have to travel                                   chosen the images purely for illustration because this
                             upwards which would increase the head height and                                    graph is slightly different for each pump.) The example
                             may stop the water returning to the pond via gravity.                               pump that can move 13,000 litres per hour (Qmax L/h)
                             But in general, if the water is delivered from the pond                             without resistance, falls back to about half at about
                             to the bottom of a filter then there is no increased head                           7,000 litres per hour at 2 metres of head height. The
                             height provided the water level in this filter is equal to                          pump uses the same amount of energy (watts) to do
                             that in the pond (Pump-Fed System).                                                 this. Now 2 metres is already a very large waterfall and
                                                                                                                 high trickle filter but even at 1 metre this is in the same
                             A waterfall clearly has a head height and thus causes                               example up to 9,500 litres. So do you have a pond of
                             losses. You pump water up and from there it falls back                              12m³ and do you want to pump it around once an hour?
                             into your pond to the water level in your pond. A trickle                           Then decide what your head height will be. Purely from
                             filter can be seen as a kind of waterfall and therefore a     WHAT IS THE           the head height, this pump will work with a gravity
                             filter with a large head height. What is the impact of        IMPACT OF             system, so without a head height loss, but if you simply
                             this head height on the amount of water a pump can                                  put your filter next to a low pond without digging in the
                             move? Well, a lot.                                            THIS HEAD             filter thereby creating a head height loss of 1 metre, then
                                                                                           HEIGHT ON             you won’t pump enough water around with this pump.
       THE HIGHER
                                 7m            1,000 l/h                                   THE AMOUNT           7
       THE HEAD                                                                            OF WATER A                Hmax (M)  3500  5000 6500 8000  10000 13000  15000 18000 20000
       HEIGHT, THE               6m            2,000 l/h                                   PUMP CAN             6
       LESS WATER                5m            3,000 l/h                                   MOVE?                5

       COMES OUT
                                                                                                                4
       OF THE HOSE               4m            4,000 l/h
       OR PIPE                                                                                                  3
                                 3m            5,000 l/h
                                                                                                                2
                                 2m            6,000 l/h
                                                                                                                1
                                                                                                                                                            Qmax (L/h)
                                 1m            7,000 l/h
                                                                                                                0
                                                                                                                     2000  4000  6000  8000 10000 12000 14000 16000 18000 20000

                                                                                                                 Resistance
                                                                                                                 Now there are a few more factors to consider here such
                                                                                                                 as pipe resistance and pump design. Looking at
                                                                                                                 resistance first, every metre of pipe or hose and at
                                                                                                                 every bend the pump encounters more resistance
                                                                                                                 which makes it more difficult to pump the same amount
                                                                                                                 of water through the pipe (and filter) which cannot be

                                          64                                                                                  65
   60   61   62   63   64   65   66   67   68   69   70