Page 69 - Koi Net - On-Line Koi Magazine - Issue 36
P. 69

is the pressure that equals a water column of 10 metres                             may be that a 20m³ pump only moves 2.5m³ to 4m³ of
                             height. That’s the pressure to overcome the height                                  water per hour. That’s much less than what it takes to
                             difference. But pressure is also needed to overcome                                 drain the dirt from the pond. The choice of too thin a
                             the resistance in the piping.                                                       pipe is often the biggest cause of dirt accumulation!
                                                                                                                 So don’t look at the connections of your filters or
                             Let’s say the piping is 50mm. We need a certain                                     pumps, but decide what you actually want to pump
                             pressure to squeeze through 20m³ of water per hour.                                 in m³ or gallons of water per hour. Of course, the
                             That pressure must lift the resistance pressure in the                              mentioned connections are constrictions in your piping,
                             piping and then overcome the height difference. A pipe                              but they have much less influence than complete piping
                             of Ø 50mm has per metre (!) a counter pressure equal                                with such a diameter.
                             to a head height between 0.5 and 0.7 metres of water:
                             0.05 to 0.07 bar. So if you have 10 metres of piping
                                                                                                                             When choosing your piping
                             before and after the pump, including bends, etc.,
                             that means 5 to 7 metres theoretical head height,                                    Ø 50mm minimum at a pump of 5m³ per hour
                             or: 0.5 to 0.7 bar.
                                                                                                                  Ø 63mm minimum at a pump of 10m³ per hour
                             So if you have 10 metres of pipework before and after
                             the pump, including bends and the like, this means                                   Ø 75mm minimum at a pump of 15m³ per hour
                             5 to 7 metres theoretical feed height, i.e.: 0.5 to 0.7 bar.
                                                                                                                  Ø 90mm minimum at a pump of 20m³ per hour
                             Now we’re trying to find a pump that with that head
                                                                                                                  Ø 110mm at pumps that can move more than 20m³ per hour
                             height (= pressure) could still displace 20m³ per hour
                             through that 50mm piping, we find that with the pumps
       WE NEED A             we know in the pond world, this is virtually impossible!      THE CHOICE            In exceptional cases, it is even beneficial to have
                                                                                                                 Ø 125mm piping. It is always interesting to have your
       CERTAIN               There are only a few pumps capable of doing this. We’ll       OF TOO THIN           situation viewed or calculated before you start. Often
                             talk about a pump that, with the right piping, can deliver                          the different installation and/or increase of the piping is
       PRESSURE              50m³ per hour. However, they use 500 watts of power.          A PIPE WILL           much more advantageous than choosing a completely

       TO OVERCOME           You’re going to notice that in your power bill. The           CAUSE THE             new filter line.
                             conclusion is that Ø 50mm piping is absolutely the
       THE HEAD              wrong choice!                                                 BUILD UP OF           Let’s talk about the pusher pump we talked about
       HEIGHT                If we were to make the same calculation with, for             DIRT IN YOUR          before. Of course, according to the choice of the
                                                                                                                 thickness of the pipes to the size of the connections of
                             example, Ø 90mm of piping, we see that per metre
       DIFFERENCE            the resistance is only 2cm higher and therefore at            PIPEWORK              the pump or the filter. Often people think that if a pump
                                                                                                                 has a certain maximum flow (= liquid displacement per
                             10 metres only 20cm. There are numerous pumps for
                                                                                                                 hour in litres), this is by definition achieved, regardless
                             sale with which we can then move that 20m³ per hour
                                                                                                                 of the choice of piping. This confusion arises mainly
                             of water in our system.
                                                                                                                 because a centrifugal pump is then confused in terms
                             The energy required is therefore more budget friendly.                              of operation with a push pump. The latter works
                             Namely, 75 watts instead of 500 watts. By choosing the                              according to the principle of a cylinder and piston.
                             right thickness for the piping, you save energy in this
                                                                                                                 Suppose we have a push pump with a cylinder that can
                             case: about €€850 = per year while you are still moving
                                                                                                                 hold 2 litres of water when the piston is in the most
                             20m³ per hour of water.
                                                                                                                 extended position. Then 2 litres will be pressed or
                             We can also approach it the other way around. We start                              sucked in at each stroke of the piston. Think of your
                             again from a Ø 50mm pipe that is 10 metres long and                                 bicycle pump, for example. In fact, you make two
                             has 5 metres head height loss due to friction. Then it                              movements: pulling out and squeezing away. With each
                                          68                                                                                  69
   64   65   66   67   68   69   70   71   72   73   74